Full Generator - Türkiye

Diesel Generators


 
 
 
FB 150

FB 150

  • Engine: BAUDOUIN
  • Engine Model : 6M11G150/5
  • Stand By kVA: 150
  • Stand By kW : 120
  • Prime kVA: 136
  • Prime kW : 109
  • Rated Current :
SPECFICATIONS
Engine
- BAUDOUIN heavy duty diesel engine
- 12V starter and charge alternator
- Replaceable air, fuel and oil filters
- Mechanical governor control
- Tropical type radiator
- Flexible fuel hose
- Oil drain valve and extension hose
- Industrial type silencer and steel compensator
- Maintenance-free starter battery
- Water jacket heater
- 1500 rpm engine speed
Sound Proof Canopy and Chassis
- Convenient design for easy lifting and carrying
- High standard sound proof canopy design
- Modular design with easily removable nuts - bolts
- Lockable doors
- Transparent window for watching Control Panel
- Electrostatic powder painted, providing protection against harsh weather conditions
- Emergency STOP button
- Fuel tank inside the chassis
- Anti-vibration wedges (engine - chassis and chassis – ground)
Alternatör
- IP 21-23 Protection Standard
- H Insulation Class
- 50 Hz Frequency
- 4 pole brushless synchronous type alternator
- Automatic Voltage Regulator (AVR)
- 400/230V AC Output Voltage - 1500 rpm
Optional
- Thermal magnetic CB (for automatic models)
- Super Silent Canopy
- Mobile Generator Sets
- Automatic fuel filling system
- Synchronization panel
- 3 Pole and 4 Pole ATS (Automatic Transfer Switch)
- Fuel Heater, Oil Heater
- External fuel tank and automatic fuel filling system
- Fuel - water separator filter
- Remote monitoring and control system
ENGINE
Engine   BAUDOUIN
Engine Model   6M11G150/5
Number of Cylinders   6 Inline
Injection System   Direct
Compression Ratio   18:1
Bore   105
Strok   130
Displacement lt 6,75
Air Intake   Turbocharge& Aftercooled
Speed (RPM)   1500
Oil Capacity lt 17
Standby Power kW / hp 140/187
Prime Power kW / hp 128/171
Fuel Type   Euro Diesel
Governor System   Electronic
Cooling System   Water Cooling
Coolant Capacity lt 20
Fuel Consumption (lt / h) lt Full Load 30,2
lt %75 LOAD 23
lt %50 LOAD 15,9
ALTERNATOR
Frequency Hz 50
Power kVA 152
Voltage V 400 V
Number of Phases   3
Automatic Voltage Regulator (A.V.R.)  
Voltage Regulation   ±1%
Insulation Class   H
Protection Standard   IP23
Power Factor   0.8
DIMENSIONS
Weight (Silent) kg 1995
Weight (Open) kg 1735
Width (Silent) mm 1000
Length (Silent) mm 3150
Height (Silent) mm 1700
Fuel Tank Capacity lt 220
1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isn’t permissible.
2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
Topçular A.Ş. reserves the right to make changes in model, technical specifications, color, equipment & accessories without prior notice.