Full Generator - Türkiye

Diesel Generators


 
 
 
FC 88

FC 88

  • Engine: CUMMINS
  • Engine Model : 4BTA3.9-G11
  • Stand By kVA: 88
  • Stand By kW : 70,4
  • Prime kVA: 80
  • Prime kW : 64
  • Rated Current : 115
SPECFICATIONS
Engine
- CUMMINS heavy duty diesel engine
- 12V starter and charge alternator
- Replaceable air, fuel and oil filters
- Mechanical governor control
- Tropical type radiator
- Flexible fuel hose
- Oil drain valve and extension hose
- Industrial type silencer and steel compensator
- Maintenance-free starter battery
- Water jacket heater
- 1500 rpm engine speed
Sound Proof Canopy and Chassis
- Convenient design for easy lifting and carrying
- High standard sound proof canopy design
- Modular design with easily removable nuts - bolts
- Lockable doors
- Transparent window for watching Control Panel
- Electrostatic powder painted, providing protection against harsh weather conditions
- Emergency STOP button
- Fuel tank inside the chassis
- Anti-vibration wedges (engine - chassis and chassis – ground)
Alternatör
- IP 21-23 Protection Standard
- H Insulation Class
- 50 Hz Frequency
- 4 pole brushless synchronous type alternator
- Automatic Voltage Regulator (AVR)
- 400/230V AC Output Voltage - 1500 rpm
Optional
- Thermal magnetic CB (for automatic models)
- Super Silent Canopy
- Mobile Generator Sets
- Automatic fuel filling system
- Synchronization panel
- 3 Pole and 4 Pole ATS (Automatic Transfer Switch)
- Fuel Heater, Oil Heater
- External fuel tank and automatic fuel filling system
- Fuel - water separator filter
- Remote monitoring and control system
ENGINE
Engine   CUMMINS
Engine Model   4BTA3.9-G11
Number of Cylinders   4 Inline
Injection System   Direct
Compression Ratio   17.3: 1
Bore   102
Strok   120
Displacement L 3,9
Air Intake   Turbocharged & Aftercooled
Speed (RPM)   1500
Oil Capacity L 3,9
Standby Power kw / Hp 80 / 107
Prime Power kw / Hp 70 / 93
Fuel Type   Euro Diesel
Governor System   Mechanical
Cooling System   Water Cooling
Coolant Capacity L 8,3
Fuel Consumption (lt / h) L Full Load 17,6
L %75 LOAD 13,2
L %50 LOAD 9,1
ALTERNATOR
Frequency Hz
Power kVA 88
Voltage V 230 / 400 V
Number of Phases   3
Automatic Voltage Regulator (A.V.R.)   AS440
Voltage Regulation   ±1%
Insulation Class   H
Protection Standard   IP22-IP23
Power Factor   0,8
DIMENSIONS
Weight (Silent) Kg 1270
Weight (Open) Kg 1076
Width (Silent) Mm 1000
Length (Silent) Mm 2800
Height (Silent) Mm 1500
Fuel Tank Capacity L 210
1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isn’t permissible.
2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
Topçular A.Ş. reserves the right to make changes in model, technical specifications, color, equipment & accessories without prior notice.